--- title: "Configure Sensor Settings on Nodegrid Device" slug: "configure-sensor-settings-on-nodegrid-device-1" updated: 2023-04-13T11:55:22Z published: 2023-04-13T11:55:22Z canonical: "docs.zpesystems.com/configure-sensor-settings-on-nodegrid-device-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.zpesystems.com/llms.txt > Use this file to discover all available pages before exploring further. # Configure Sensor Settings on Nodegrid Device To perform these procedures, log into the Nodegrid Device. ## Access sub-tab 1. Go to *Managed Devices :: Devices :: SignalTower_Alarm :: Access*. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579524910.png) 2. As needed (many of these are optional): 1. Enter **Username**. 2. Enter **Password** and **Confirm Password**. 3. Enter **Address Location**. 4. Enter **Coordinates (Lat,Lon**). 5. Click **Icon** (on pop-up, select the preferred icon). 6. On **Mode** drop-down, select one (Enabled, On-demand, Disabled, Discovered). 7. Select **Allow Pre-shared SSH Key** checkbox. 8. On **Baud Rate** drop-down, select one (Auto, 9600, 19200, 38400, 57600, 115200, 230400, 921600). On **Parity** drop-down, select one (None, Even, Odd). On **Flow Control** drop-down, select one (None, Software, Hardware). On **Data Bits** drop-down, select one (5, 6, 7, 8, Auto). On **Stop Bits** drop-down, select one (1, 2). On **RS-232 signal for device state detection** drop-down, select one (Auto, DCD, CTS, None). 9. Select **Enable device state detection based on data flow** checkbox. If selected, enter **Data flow scan interval (s)**. 10. Select **Enable Hostname Detection** checkbox. 11. Select **Multisession** checkbox. 3. On *Inbound Access* menu: 1. Select **Skip authentication to access device (NONE authentication)** checkbox. If selected, select checkboxes, as needed: **Skip in SSH sessions** checkbox **Skip in Telnet sessions** checkbox **Skip in Raw sessions** checkbox **Skip in Web sessions** checkbox 2. Enter **Escape Sequence** (default: ^Ec). 3. Enter **Power Control Key** (default: ^O). 4. Select **Show Text Information** checkbox. 5. Select **Enable IP Alias** checkbox (extends dialog).![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579590406.png)Enter **IP Address**. On **Interface** drop-down, select one. On **Browser Action** drop-down, select one. Select **Allow Telnet Protocol** checkbox. Enter **TCP Socket Port** (default: 23). 6. Select **Enable second IP Alias** checkbox (repeats above) 7. Select **Allow SSH Protocol** checkbox (extends dialog). Enter **SSH Port**.![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579635537.png) 8. Select **Allow Telnet protocol** checkbox (extends dialog). Enter **Telnet Port**.![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579662452.png) 9. Select **Allow Binary Socket** checkbox (extends dialog). Enter **TCP Socket Port**.![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579686681.png) 4. Click **Save**. ## Management sub-tab 1. Go to *Managed Devices :: Devices :: SignalTower_Alarm :: Management*. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579708367.png) 2. In the *Monitoring* menu, select **Nominal** checkbox (expands dialog). ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579737812.png) 1. Enter **Name**. 2. On **Type** drop-down, select one. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579756584.png) 3. Enter **Value**. 4. Enter **Interval (s)**. 3. In the *Scripts* menu (if scripts are available): ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579790418.png) 1. On **Run on Session Start** drop-down, select a script. 2. On **Run on Session Stop** drop-down, select a script. 3. On **Run on Device UP** drop-down, select a script. 4. On **Run on Device Down** drop-down, select a script. 4. Click **Save**. ## Custom Fields sub-tab 1. Go to *Managed Devices :: Devices :: SignalTower_Alarm :: Custom Fields*. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579809402.png) 2. To create a custom field, click **Add** (display’s dialog). 1. Enter **Field Name**. 2. Enter **Field Value**. 3. Click **Save**. ## Commands sub-tab 1. Go to *Managed Devices :: Devices :: SignalTower_Alarm :: Commands*. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579844812.png) 2. To create a custom command, click **Add**. 3. In **Command** drop-down select one (Web, Custom Commands). 1. Select **Web** (displays dialog). ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579888462.png)Select **Enabled** checkbox. Enter **WEB URL**. 2. Select **Custom Commands** (displays dialog). ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579910387.png)Select **Enabled** checkbox. In **Script** drop-down, select one. Select **Enabled** checkbox. Enter **Command Label**. 4. (Repeat as needed) 5. Click **Save**. ## Sensor Channels sub-tab The table displays configured sensor channels. 1. Go to *Managed Devices :: Devices :: SignalTower_Alarm :: Sensor Channels*. ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679579949408.png) 2. Click on **SignalTower_Alarm_cn0** channel (displays dialog). ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679580031193.png) 1. Edit **Name** (as needed). 2. On **Mode** drop-down, accept default: **light.** 3. On **Unit** drop-down, accept default: **Off/On/Continuous Cycle**. 3. Click on **SignalTower_Alarm_cn1** channel (di**splays dialog).** ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679580124671.png) 1. Edit **Name** (as needed). 2. On **Mode** drop-down, accept default: **light.** 3. On **Unit** drop-down, accept default: **Off/On/Continuous Cycle.** 4. Click on **SignalTower_Alarm_cn2** channel (di**splays dialog).** ![](https://cdn.document360.io/763c5fb1-b9af-4ccd-9ad6-cf28ae4cd5a3/Images/Documentation/image-1679580158414.png) 1. Edit **Name** (as needed). 2. On **Mode** drop-down, accept default: **buzzer.** 5. On **Unit** drop-down, accept default: **Off/On/Continuous Cycle.** 6. Click **Save**.