--- title: "How to Deploy a Nodegrid Appliance" slug: "how-deployment-guide" updated: 2024-08-13T10:24:47Z published: 2024-08-13T10:24:47Z canonical: "docs.zpesystems.com/how-deployment-guide" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.zpesystems.com/llms.txt > Use this file to discover all available pages before exploring further. # How to Deploy a Nodegrid Appliance This document outlines best practices and an example of how Service Contractors can deploy a Nodegrid appliance as part of racking and stacking service contracts. While the Nodegrid appliances support a wide range of deployment options, including Zero Touch Provisioning, supported by ZPE Cloud, is the traditional model of deployment through on-site engineers still quite common. This guide covers the *example* deployment of a NetSR in a co-lo data center through an on-site engineer with little to no Nodegrid appliance experience. The deployment is supported remotely by an experienced engineer. The deployment aims to rack-mount the appliance and provide a base configuration that allows the engineers to validate the connectivity to a Nodegrid Cluster Coordinator or ZPE Cloud. The configuration can contain basic network configuration details, like setting of static IP Address details, creation of LACP bonds or the connectivity to management VLANs. A typical deployment through a remote engineer involves, in most cases, two personas. - Network Architect/Engineer: This person understands the Nodegrid solution and its workings well. They aim to gain access to the appliance remotely to complete the deployment of the device and the site/location. - On-Site Engineer/"Smart-Hands": This person has physical access to the location and is enabled to install a new appliance, but the person has little to no experience with the Nodegrid solution. The guides draw on experiences from many customer deployments and aim to make deployments repeatable and consistent, especially in environments without ZPE Cloud. ### **Benefits** - Make Nodegrid deployments easy, repeatable and consistent - faster deployments - more consistent configurations ### Deployment Preparation This section outlines which preparation should be performed before the actual installation and deployment of the NetSR appliance by each persona. #### **Network Architect/Engineer** - Create a configuration template for the base configuration using import_settings commands. - Decide on a target Nodegrid OS version, which should be deployed initially - Create a deployment check and instructions for the on-site engineer to follow - Create the specific configuration for the NetSR, based on the base template - Review and share the Nodegrid Safety details with the On-Site Engineer. The details can be found [here](https://docs.zpesystems.com/docs/safety). #### On-Site Engineer/"Smart-Hands" - Prepare a laptop which can be used for the deployment, the laptop should have a network interface (Ethernet) for access via SSH/WebUI and a Serial Console connection (recommended) - The console cable, the required cable and the adapter for a DB9 Serial adapter are part of the box. As an alternative, can the engineer use an existing Cisco console cable - a USB memory stick, min size 2GB, with the correct Nodegrid firmware. Only required if network access is not possible - Access to the Nodegrid OS firmware file (.iso) - All other materials required to install the appliance, like power cables, network cables etc. - Review the Nodegrid ## Step by Step - Deployment - For the physical installation of the NetSR and connection of cables, see the [hardware installation](https://docs.zpesystems.com/docs/hardware-installation) section for more details. - Power on the unit - Connect the laptop via serial console [to the Nodegrid console port](https://docs.zpesystems.com/docs/connect-to-the-console-port). (Baud: 115200,8,N,1,N) - The Console connection will display the boot process. The console connection will display the login prompt after a few minutes, typically 2-5 min. If required, press ENTER, to display the login prompt. - Login to the Nodegrid appliance with the default credentials: ***admin/admin*** - During the first login **must**, the user change the default password to a new secure password (min 8 characters, with a number and a special character) - Perform a Firmware update with a reformat of the portion; [see for instructions](/guides/docs/how-deployment-guide#firmware-update-via-usb-stick) - Wait until the firmware upgrade process is completed (5-10min) - Login to the Nodegrid appliance with the default credentials: ***admin/admin*** - During the first login **must**, the user change the default password to a new secure password (min 8 characters, with a number and a special character) - [Validate the firmware version](/guides/docs/how-deployment-guide#check-firmware-version) - [Apply base configuration template](/guides/docs/how-deployment-guide#apply-base-configuration) - [Validate connectivity and configuration](/guides/docs/how-deployment-guide#validate-connectivity-and-configuration) ## Instructions ### Validate Firmware Version - Starting from the admin CLI prompt (after login) - check the firmware version with ```shell show /system/about ``` Example Output ```shell [admin@nodegrid /]# show /system/about/ system: Nodegrid Net SR licenses: 40 software: v5.8.13 (Sep 7 2023 - 03:00:38) cpu: Intel(R) Atom(TM) CPU C3758 @ 2.20GHz cpu_cores: 8 bogomips_per_core: 4400.00 serial_number: 401900000 uptime: 30 days,  22 hours,  50 minutes boot mode: Legacy secure boot: Disabled model: NSR part_number: NSR-TOP1-DAC bios_version: 80919T00 psu: 2 revision tag: INITIAL-CONFIG bios sed compatible: no ssd sed compatible: no sed pba version: no ``` ### Apply Base Configuration - Starting from the admin CLI prompt (after login) - use the following commands to apply a provided import_settings template ```shell import_settings ``` - Press CTRL+D to commit the changes. - Validate that ***no*** path was rejected - Example ```shell [admin@nodegrid /]# import_settings Type or paste data output from export_settings. Press to finish. /settings/network_settings hostname=nsr01 /settings/network_settings domain_name=zpecloud.com Path: /settings/network_settings Result: succeeded Processed paths: 1 Rejected paths: 0 ``` ### Validate connectivity and configuration #### Check the firmware version and serial number ```shell show /system/about/ ``` The output should contain: - **software**: version should match the specified version ```shell [admin@nodegrid /]# show /system/about/ system: Nodegrid Net SR licenses: 40 software: v5.8.13 (Sep 7 2023 - 03:00:38) cpu: Intel(R) Atom(TM) CPU C3758 @ 2.20GHz cpu_cores: 8 bogomips_per_core: 4400.00 serial_number: 401900000 uptime: 30 days,  22 hours,  50 minutes boot mode: Legacy secure boot: Disabled model: NSR part_number: NSR-TOP1-DAC bios_version: 80919T00 psu: 2 revision tag: INITIAL-CONFIG bios sed compatible: no ssd sed compatible: no sed pba version: no ``` #### Check the network connection information ```shell show /settings/network_connections/ ``` The output should contain: - **carrier state** for a required interface be ***up*** - **ipv4 address** should display a valid IP address the **interface** name of a VLAN interface should be of the format ., i.e. eth0.254 ShellShell ```shell [admin@nsr01 toolkit]# show /settings/network_connections/  name         status      type                  interface   carrier state  ipv4 address       ipv6 address                  mac address        description  ===========  ==========  ====================  ==========  =============  =================  ============================  =================  ===============  BACKPLANE0   connected   ethernet              backplane0  up             172.16.0.2/24      fe80::e61a:2cff:fe00:7501/64  e4:1a:2c:00:75:01  BACKPLANE1   connected   ethernet              backplane1  up                                                              e4:1a:2c:00:75:02  BRIDGE       connected   bridge                br1         up                                                              96:10:3a:f5:77:4f  ETH0         connected   ethernet              eth0        up             192.168.1.2/24      fe80::e61a:2cff:fe00:74ff/64 e4:1a:2c:00:74:ff  OOBI-WAN  VLAN254      connected   vlan                  eth0.254    up             192.168.254.2/24    e4:1a:2c:00:74:ff                               OOBI-WAN  CELLULAR-A   connected   mobile broadband gsm  cdc-wdm7    up             10.177.183.245/30                                                   OOBI-WAN BACKUP  hotspot      not active  wifi                              down  loopback2    connected   loopback              loopback2   up             10.244.255.193/32                                c2:4e:77:c3:0e:34  loopback1    connected   loopback              loopback1   up             10.250.0.1/24                                    46:c9:6a:94:0c:4d ``` #### Check network switch interface information ```shell show /settings/switch_interfaces/ ``` The output should contain: - **status***: should be* ***enabled*** for interfaces that should be in use - **speed**: should be on **Auto** or a specific speed as defined in the configuration - **port vlan id**: for an access port it should contain the correct VLAN id, for a trunk interface it will show the default VLAN id ```shell [admin@nsr01 toolkit]# show /settings/switch_interfaces/  interface  status    description  speed  port vlan id  jumbo frame  acl ingress  acl egress  dhcp snooping  mstp status  802.1x status  =========  ========  ===========  =====  ============  ===========  ===========  ==========  =============  ===========  =============  sfp0       Enabled                Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  sfp1       Enabled                Auto   2             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-1    Enabled      LAN01     Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-2    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-3    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-4    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-5    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-6    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-7    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-8    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-9    Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-10   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-11   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-12   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-13   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-14   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled  netS3-15   Disabled               Auto   250           Disabled     None         None        Untrusted      Disabled     Disabled  netS3-16   Disabled               Auto   1             Disabled     None         None        Untrusted      Disabled     Disabled ``` #### Check network switch VLAN information ```shell show /settings/switch_vlan/ ``` The output should contain: - **vlan***: should contain vlan 1,2 and any added VLAN ID* - **untagged/tagged ports**: should contain the desired interfaces ```shell [admin@nsr01 toolkit]# show /settings/switch_vlan/  vlan  untagged ports                                               tagged ports  ====  ===========================================================  ============  1     backplane0, netS3-[1..14], netS3-16, sfp0, slot2-0, slot2-1  2     backplane1, sfp1  250   netS3-15                                                     netS3-16  251                                                                netS3-16 ``` #### Check network switch LAG information ```shell show /settings/switch_lag/ ``` The output should contain: - **type**: should match LACP - **ports**: should contain the assigned ports ```shell [admin@nsr01 /]# show /settings/switch_lag/  name  id  type  ports  ====  ==  ====  ==========  lag   1   LACP  sfp0, sfp1 ``` #### Check SFP details ```shell show /system/switch_statistics/sfp0 show /system/switch_statistics/sfp1 ``` The output should contain: - **status***: Enabled* - **state**: Up - **speed**: 1G or 10G, depending on the configuration ```shell [admin@nsr01 toolkit]# show /system/switch_statistics/sfp0 interface: sfp0 status: Enabled state: Down speed: 10G rx packets: 0 rx bytes: 0 tx packets: 0 tx bytes: 0 --- SFP Information --- identifier: 0x03 (SFP) extended identifier: 0x04 (GBIC/SFP defined by 2-wire interface ID) connector: 0x07 (LC) transceiver codes: 0x10 0x00 0x00 0x00 0x40 0x00 0x0c 0x00 0x00 transceiver type: 10G Ethernet: 10G Base-SR transceiver type 2: FC: short distance (S) transceiver type 3: FC: Multimode, 62.5um (M6) transceiver type 4: FC: Multimode, 50um (M5) encoding: 0x06 (64B/66B) br, nominal: 10300MBd rate identifier: 0x00 (unspecified) length smf,km: 0km length smf: 0m length 50um: 300m length 62.5um: 150m length copper: 0m length om3: 0m laser wavelength: 850nm vendor name: ZPE ``` #### Ping default gateway ```shell shell ping 192.168.1.1 -c 3 ``` The output should contain: - **3** **packets transmitted,** **3** **received,** **0****% packet loss** ```shell [admin@nsr01 toolkit]# shell ping 192.168.1.1 -c 3 PING 192.168.1.1 (192.168.1.1) 56(84) bytes of data. 64 bytes from 192.168.1.1: icmp_seq=1 ttl=64 time=0.258 ms 64 bytes from 192.168.1.1: icmp_seq=2 ttl=64 time=0.229 ms 64 bytes from 192.168.1.1: icmp_seq=3 ttl=64 time=0.221 ms --- 192.168.1.1 ping statistics --- 3 packets transmitted, 3 received, 0% packet loss, time 2055ms rtt min/avg/max/mdev = 0.221/0.236/0.258/0.015 ms ``` #### Validate DNS ```shell shell ping zpecloud.com -c 3 ``` The output should contain: - **3** **packets transmitted,** **3** **received,** **0****% packet loss** ```shell [admin@nsr01 toolkit]# shell ping zpecloud.com -c 3 PING zpecloud.com (34.83.37.8) 56(84) bytes of data. 64 bytes from 8.37.83.34.bc.googleusercontent.com (34.83.37.8): icmp_seq=1 ttl=104 time=181 ms 64 bytes from 8.37.83.34.bc.googleusercontent.com (34.83.37.8): icmp_seq=2 ttl=104 time=165 ms 64 bytes from 8.37.83.34.bc.googleusercontent.com (34.83.37.8): icmp_seq=3 ttl=104 time=149 ms --- zpecloud.com ping statistics --- 3 packets transmitted, 3 received, 0% packet loss, time 2003ms rtt min/avg/max/mdev = 149.455/165.323/181.106/12.921 ms ``` #### Test mobile connection (4G/5G) Interface Name The 4G/5G interface number will change depending on the Nodegrid model and in which slot it might be installed. The interface will always be wwanX, where by X stands for interface number. To identify the correct interface number to use, identify the assigned interface, for network_connections output, for example: CELLULAR-A connected mobile broadband gsm cdc-wdm7 cdc-wdm7 corresponds to wwan7 ```shell shell ping 1.1.1.1 -I wwan7 -c 3 ``` The output should contain: - **3** **packets transmitted,** **3** **received,** **0****% packet loss** ```shell [admin@nsr01 toolkit]# shell ping 1.1.1.1 -I wwan7 -c 3 PING 1.1.1.1 (1.1.1.1) from 10.177.183.245 wwan7: 56(84) bytes of data. 64 bytes from 1.1.1.1: icmp_seq=1 ttl=56 time=154 ms 64 bytes from 1.1.1.1: icmp_seq=2 ttl=56 time=100 ms 64 bytes from 1.1.1.1: icmp_seq=3 ttl=56 time=65.7 ms --- 1.1.1.1 ping statistics --- 3 packets transmitted, 3 received, 0% packet loss, time 2002ms rtt min/avg/max/mdev = 65.746/106.673/154.013/36.318 ms ``` #### Check the ZPE Cloud connection ```shell show /system/zpe_cloud/ ``` The output should contain: - **associated company**: should be the company name - **status**: Connected - Licensed - **URL**: [https://zpecloud.com](https://zpecloud.com) for US instance or [https://zpecloud.eu](https://zpecloud.eu) for EU instance ```shell [zpeadmin@iensr01 toolkit]# show /system/zpe_cloud/ device id: ZSnIZLaUVCGq5Sp1000000 associated company: ZPE Systems associated site: US status: Connected - Licensed last public ip connected: 109.78.0.60 total of exchanged messages: 1280290 total of exchanged bytes: 322293554 url: https://zpecloud.com version: 2.30.0 device registration: 25/02/2020 10:23:31 UTC first connection: 05/12/2022 14:56:40 UTC last reconnection: 28/11/2023 08:07:20 UTC last disconnection: 28/11/2023 07:55:25 UTC ``` ### Firmware Update via USB stick Assumption The Nodegrid firmware file, for example, Nodegrid_Platform_v5.10.8_20231107.iso is in the root folder of the USB stick. Firmware File Name The firmware file name must end in .iso. The firmware process will not be successful if the file ending is not .iso - Connect the USB stick to any of the USB ports on the device - Starting from the admin CLI prompt (after login) use the following commands to copy the file to the Nodegrid appliance - navigate to the root shell ```shell shell sudo su - ``` - Navigate to the USB location ```shell cd /run/media/sdb1 ``` - Copy the firmware file to /var/sw/ and validate the file ```shell cp ./Nodegrid_Platform_v5.10.8_20231107.iso /var/sw/ ls -lh /var/sw/ ``` - disconnect the USB stick - Return to the admin CLI prompt ```shell exit ``` - Perform the firmware update and reset the unit to factory defaults in one step ```shell software_upgrade set filename=Nodegrid_Platform_v5.10.8_20231107.iso set format_partitions_before_upgrade=yes upgrade ```