Nodegrid Release Notes 6.2.2

Prev Next

These Release Notes apply to the Nodegrid devices. They list the supported device models, upgrade instructions, software components information, security fixes, new and changed functionalities, and fixed issues in the hardware and software.

You can also find information on providing documentation feedback and accessing product troubleshooting resources.

For detailed information on Nodegrid, see the latest version of the Nodegrid User Guide.

Nodegrid Version 6.2.2

Release February 11, 2026

Supported Products

  • Nodegrid Manager

  • Nodegrid Serial Console Plus - Core Edition

  • Nodegrid Serial Console

  • Nodegrid Bold SR

  • Nodegrid Gate SR

  • Nodegrid Link SR

  • Nodegrid Net SR

  • Nodegrid Hive SR

  • Nodegrid Mini SR

Upgrading Instructions

  • Upgrade methods from Web Interface, CLI, USB, Network Boot, and ZPE Cloud are supported.

  • UEFI mode and Secure Boot must be disabled before downgrading to v5.0 or older.

  • Upgrades from v4.x versions is only supported starting at v4.2.4.

  • Upgrade from v3 versions is only supported for Nodegrid Serial Console devices at v3.2.54 and will erase existing data in the /var directory.

Software Components Information

Component

Filename

MD5 Checksum

Software ISO

Nodegrid_Platform_v6.2.2_20260204.iso

cd84f10dc6e149a09441c7cfb139fa90

Network Boot

Nodegrid_NetBoot_v6.2.2_20260204.tar.gz

9b8f2127d6eb8d8ab85e588d3aa5d49c

SNMP MIB

Nodegrid_MIB_v6.2.2_20260204.zip

abf15e4943f536a2a9a6e0f4ce9d4e28

Security Fixes

  • Patched OpenSSL v3.0.12 (CVE-2025-15467).

  • Patched inetutils v2.2 (CVE-2026-24061).

  • Upgraded Firefox to v147.0.1 (CVE-2026-0879, CVE-2026-0881, CVE-2026-0884, CVE-2026-0892, CVE-2025-14860, CVE-2025-14324, CVE-2025-14326, CVE-2025-14330, CVE-2025-13021, CVE-2025-13022, CVE-2025-13023, CVE-2025-13024, CVE-2025-13026).

  • Upgraded freerdp to v3.21.0 (CVE-2026-22852, CVE-2026-22853, CVE-2026-22854, CVE-2026-22855, CVE-2026-22857, CVE-2026-22858, CVE-2026-22859).

  • Patched zlib v1.2.11 (CVE-2026-22184).

  • Patched python3 v3.10.16 (CVE-2025-13836).

  • Patched samba v4.18.8 (CVE-2025-10230).

Fixed Issues

  • Fixed a deadlock condition in network failover daemon.

  • Fixed an issue introduced in v6.2.1 where some older device hardware models would fail to detect the TPM module and be unable to connect to ZPE Cloud.

  • Fixed input validation of the field /settings/certificates/subject_alternative_names when creating self-signed certificates.

  • Fixed SNMP query of SFP-related OIDs taking unnecessarily long.

  • Fixed discovery of Console Server Raritan ports not working when there is a period in the name.

  • Fixed an issue where changing security/TLS settings via API could return a connection error when the settings were applied, by improving the web server restart behavior.

  • Allow MSTP configuration using VLANs that are not yet configured.

  • Fixed an issue where the GSR, BSR and LSR ETH0 continued to advertise all speeds after selecting the 1G/Full link mode.

  • ZPE Cloud - Fixed an issue where Nodegrid Status was displaying Failover after connection list was deleted from Failover configuration.

  • ZPE Cloud - Fixed an issue that prevented a device to connect to ZPE Cloud once FIPS 140-3 was enabled.

Nodegrid Version 6.2.1

Release December 17, 2025

Supported Products

  • Nodegrid Manager

  • Nodegrid Serial Console Plus - Core Edition

  • Nodegrid Serial Console

  • Nodegrid Bold SR

  • Nodegrid Gate SR

  • Nodegrid Link SR

  • Nodegrid Net SR

  • Nodegrid Hive SR

  • Nodegrid Mini SR

Upgrading Instructions

  • Upgrade methods from Web Interface, CLI, USB, Network Boot, and ZPE Cloud are supported.

  • UEFI mode and Secure Boot must be disabled before downgrading to v5.0 or older.

  • Upgrades from v4.x versions is only supported starting at v4.2.4.

  • Upgrade from v3 versions is only supported for Nodegrid Serial Console devices at v3.2.54 and will erase existing data in the /var directory.

Software Components Information

Component

Filename

MD5 Checksum

Software ISO

Nodegrid_Platform_v6.2.1_20251207.iso

a364d6cb51afaf7c75f0e6e228bdff0a

Network Boot

Nodegrid_NetBoot_v6.2.1_20251207.tar.gz

3f77d6f02cc4f24489e820eea602b599

SNMP MIB

Nodegrid_MIB_v6.2.1_20251207.zip

9d142711c915c8472298eff0d377cc17

New Features and Enhancements

  • General availability release including the features from 6.2.0 Beta release.

  • Enhanced Central Management with several improvements:

    • Playbooks now run in the background, making it possible to continue working without interruption.

    • Added advanced troubleshooting with the Ansible Debug option (-vvv).

    • Introduced a new Logs tab to easily view the history and details of all playbook runs.

Fixed Issues

  • Fixed an issue where the GSR, BSR and LSR ETH0 continued to advertise all speeds after selecting the 1G/Full link mode.

  • Fixed an issue where network access on ETH0 could be lost after changing certain security settings or switching profiles. Now, the device remains accessible without requiring a reboot.

  • Fixed an issue, on the TRACKING::DEVICES::WIRELESS MODEM page, where the signal strength displayed in the Nodegrid interface did not match the value shown by the track-signal.sh script.

Nodegrid Version 6.2.0 - Beta

Release November 26, 2025

Supported Products

  • Nodegrid Manager

  • Nodegrid Serial Console Plus - Core Edition

  • Nodegrid Serial Console

  • Nodegrid Bold SR

  • Nodegrid Gate SR

  • Nodegrid Link SR

  • Nodegrid Net SR

  • Nodegrid Hive SR

  • Nodegrid Mini SR

Upgrading Instructions

  • Upgrade methods from Web Interface, CLI, USB, Network Boot, and ZPE Cloud are supported.

  • UEFI mode and Secure Boot must be disabled before downgrading to v5.0 or older.

  • Upgrades from v4.x versions is only supported starting at v4.2.4.

  • Upgrade from v3 versions is only supported for Nodegrid Serial Console devices at v3.2.54 and will erase existing data in the /var directory.

Software Components Information

Component

Filename

MD5 Checksum

Software ISO

Nodegrid_Platform_v6.2.0_20251125.iso

9587ff4c251f7e6b7f5c0c0556d73ebd

Network Boot

Nodegrid_NetBoot_v6.2.0_20251125.tar.gz

5fc879cbc547b624a940bddcdda3a7f6

SNMP MIB

Nodegrid_MIB_v6.2.0_20251125.zip

21edb61df3db028006a3ed357cc34bf1

New Features and Enhancements

  • Introducing High Availability between two Nodegrid systems, with configurable Fullsync and Live Sync options. A new tracking page and enhanced interface to monitor and manage HA sync status and activities is available.

  • Improved WebUI console sessions by removing the automatic copy-to-clipboard feature when selecting text.

  • It is now possible to select text in console sessions without it being automatically copied, avoiding unwanted content being pasted.

  • Updated the database of third-party APNs to improve compatibility and connectivity with a wider range of mobile networks.

Security Fixes

  • Upgraded Linux Kernel to 6.12.47

Fixed Issues

  • Fixed issue that prevented /var partition from being cleanly unmounted at reboot, causing unnecessary journal recoveries at every boot.

  • Resolved an issue that prevented PXE boot from working with Secure Boot enabled. Now, devices can successfully boot over the network when Secure Boot is turned on.

  • Resolved an issue where CPU and system temperatures were not displayed on Bold SR models in the UI. Temperature readings now appear as expected.

  • Improved error messages when configuring bonding interfaces with invalid options like GSM interfaces. Users now receive clearer guidance to correct configuration issues.

Documentation Feedback

You can share your feedback on ZPE product documentation using the feedback option at the end of each article. After submitting your feedback, you can optionally provide your email address if you wish to be notified when the changes are made.

Troubleshooting

For the latest and detailed troubleshooting information, see the ZPE Knowledge Base site. You can also reach out to the support team via the email ID support@zpesystems.com.